RFEM Model of Office Building of Municipal Works in Kirchheim unter Teck, Germany | © Furche Geiger Zimmermann Tragwerksplaner GmbH
Office Building Timber Structure with Reinforced Concrete Elements
Number of Nodes | 455 |
Number of Lines | 606 |
Number of Members | 61 |
Number of Surfaces | 26 |
Number of Solids | 0 |
Number of Load Cases | 8 |
Number of Load Combinations | 106 |
Number of Result Combinations | 4 |
Total Weight | 655.474 tons |
Dimensions | 80.38 x 53.18 x 42.36 feet |
In the ultimate configuration of the steel joint design, you have the option to modify the limit plastic strain for welds.
Using the "Base Plate" component, you can design base plate connections with cast-in anchors. In addition to plates and welds, the design analyzes the anchorage and the steel-concrete interaction.
In the "Edit Section" dialog box, you can display the buckling shapes of the Finite Strip Method (FSM) as a 3D graphic.
Do you have individual column sections and angled wall geometries, and need punching shear design for them?
No problem. In RFEM 6, you can perform punching shear design not only for rectangular and circular sections, but for any cross-section shape.