96x
004074
2023-12-13

Design Configurations

In the "Steel Joint Design" folder of the navigator, two configurations are preset for the ultimate limit state design and the stiffness analysis.

Ultimate Limit State

Double-click the 1 - Default item of the "Ultimate Configurations" category. In the "Edit Ultimate Configuration" dialog box, the global settings for the design of steel joints are managed. They control the design of the Substitute Steel Joint FE Model that is created in the background for the connection.

In the "General" category, the "Perform buckling analysis" is deactivated by default. This is adequate, as no effects of plate buckling will occur for rolled cross-sections.

Once you have checked the parameters, click OK to close the dialog box.

Stiffness Analysis

Double-click the 1 - Initial stiffness | No interaction item of the "Stiffness Analysis Configurations" category. In the "Edit Stiffness Analysis Configuration" dialog box, the global settings for the design of steel joints are managed. The "Initial Stiffness" analysis type is set by default. This means that the program classifies the connection according to its rotational stiffness Sj,ini as rigid, semi-rigid, or pinned. This approach ensures safety, optimizes material usage, and is consistent with the building code requirements.

Once you have checked those parameters as well, click OK to close the dialog box.