Elastic foundation coefficients are calculated according to the non-linear iterative method. The module determines elastic foundation coefficients for each individual element. They are dependent on the deformation.
In the Timber Design add-on for RFEM, you can design members as well as surfaces according to Eurocode 5, SIA 265 (Swiss standard), CSA O86 (Canadian standard), or ANSI/AWC NDS (American standard); for example, cross-laminated timber, glued-laminated timber, softwood, mass timber, and so on.
Various design parameters of the cross-sections can be adjusted in the serviceability limit state configuration. The applied cross-section condition for the deformation and crack width analysis can be controlled there.
For this, the following settings can be activated:
Crack state calculated from associated load
Crack state determined as an envelope from all SLS design situations
Cracked state of cross-section - independent of load
The design of cold-formed steel members according to the AISI S100-16 / CSA S136-16 is available in RFEM 6. Design can be accessed by selecting “AISC 360” or “CSA S16” as the standard in the Steel Design Add-on. “AISI S100” or “CSA S136” is then automatically selected for the cold-formed design.
RFEM applies the Direct Strength Method (DSM) to calculate the elastic buckling load of the member. The Direct Strength Method offers two types of solutions, numerical (Finite Strip Method) and analytical (Specification). The FSM signature curve and buckling shapes can be viewed under Sections.
The calculated stresses and settlements are displayed in result windows. In addition, it is possible to evaluate the results graphically. The graphic displays the position and the layer arrangement of the soil samples to clarify the results.
The final result window shows the elastic foundation coefficients. Graphical evaluation is possible as well.
Optional consideration of stiffening elements for transversal tension
Two design types available for stiffening elements concerning transversal tension:
Constructive if required
Full absorption of tension stresses perpendicular to grain
Calculation of required number of stiffening elements for transversal tension and graphical representation of the arrangement in the beam
Simple geometry input with illustrative graphics
Convenient generation of snow loads according to EN 1991-1-3 or DIN 1055:2005, Part 5
Automatic determination of wind loads according to EN 1991-1-4 or DIN 1055:2005, Part 4
User-defined load cases and load applications
Automatic generation of all possible load combinations
Connection to MS Excel and access via COM interface
Material library for both standards
For design according to EC 5 (EN 1995), the following National Annexes are available:
DIN EN 1995-1-1/NA:2013-08 (Germany)
NBN EN 1995-1-1/ANB:2012-07 (Belgium)
DK EN 1995-1-1/NA:2011-12 (Denmark)
SFS EN 1995-1-1/NA:2007-11 (Finland)
NF EN 1995-1-1/NA:2010-05 (France)
UNI EN 1995-1-1/NA:2010-09 (Italy)
NEN EN 1995-1-1/NB:2007-11 (Netherlands)
ÖNORM B 1995-1-1:2015-06 (Austria)
PN EN 1995-1-1/NA:2010-09 (Poland)
SS EN 1995-1-1 (Sweden)
STN EN 1995-1-1/NA:2008-12 (Slovakia)
SIST EN 1995-1-1/A101:2006-03 (Slovenia)
CSN EN 1995-1-1:2007-09 (Czech Republic)
BS EN 1995-1-1/NA:2009-10 (the United Kingdom)
Extensive library of permanent loads
Allocation of a structure to service class, and specification of service class categories
Determination of design ratios, support forces, and deformations
Info icon indicating successful or failed design
Color reference scales in result tables
Direct data export to MS Excel
DXF interface for preparation production documents in CAD
Program languages: English, German, Czech, Italian, Spanish, French, Portuguese, Polish, Chinese, Dutch, and Russian
Verifiable printout report, including all required designs. Printout report available in many output languages; for example, English, German, French, Italian, Spanish, Russian, Czech, Polish, Portuguese, Chinese, and Dutch.
In the RF-LAMINATE add-on module for RFEM, the design of torsional shear stresses in the superposition of net and gross cross-section values is possible. The design is performed separately in the x- and y-directions. The loads on the intersection points of cross-laminated timber panels are checked.
As you probably know, the design checks for the selected members are carried out, taking into account the defined charring time. All necessary reduction factors and coefficients are stored accordingly in the program and are taken into account when determining the load-bearing capacity. That saves you a lot of work.
The effective lengths for the equivalent member design are taken directly from the strength entries. You do not have to enter them again.
After completing the design, the program presents the fire resistance design checks clearly and with all result details. This allows you to follow the results completely transparently. The results also contain all the required parameters, so you can determine the component temperature at the design time.
In addition to all these features, the program allows you to integrate all result tables and graphics, including the ultimate and serviceability limit state results,into the global printout report of RFEM/RSTAB as a part of the steel design results.
In RFEM and RSTAB, you can design members with the "Laminated Veneer Lumber" material type. The following manufacturers are available:
Pollmeier (Baubuche)
Metsä (Kerto LVL)
STEICO
Stora Enso
In the ultimate configuration, you can consider strength coefficients for increasing the strengths. The coefficients reducing the strengths are automatically taken into account regardless of this. Try it now!
There are various options available for modeling a roof. Graphical representations facilitate the geometry input. Modifications are updated automatically.
In addition, it is possible to consider cross‑section weakening on supports. Optionally, you can define if the design of support pressure on the rafter side should be performed.
Permanent loads (for example, roof structure) can be entered using the comprehensive and extensible material library. Loads due to cantilevers and collars/ties can be entered separately. Generators integrated in RX-TIMBER Purlin allow for convenient generation of various wind and snow load cases. You can manually add any concentrated and distributed loads.
Load cases are displayed graphically and superimposed in automatically generated load combinations according to EC 5. For stability and serviceability limit state designs, you can change the data manually, for example, for example, for cantilevers (roof overhang), it is necessary to ignore the SLS.
The design analyzes tension and compression along the grain, bending, bending and tension or compression, and shear due to shear force with and without torsion. Designs proceed at the level of design stress values.
The design of structural components at risk of buckling or lateral buckling is performed according to the Equivalent Member Method and considers the systematic axial compression, bending with and without compression force as well as bending and tension. The deflection of inner spans and cantilevers is determined in characteristic and quasi-permanent design situations.
Separate design cases allow for a flexible and stability analysis of members, sets of members, and loads. In the case of tapered members, the cut-to-grain angle is considered in the bending tension and bending compression area. If there is a ridge defined, the module performs the ridge design additionally.
Design of foundation torsion and limitation of gaping joint
Sliding design
Settlement calculation
Bending failure design of the plate and bucket
Punching shear design
Foundation and bucket dimensions can be user-defined or determined by the module. You can edit the determined reinforcement manually. In this case, the designs are updated automatically.
The Aluminum Design add-on provides you with further options. Here you can also design general cross-sections that are not predefined in the cross-section library. For example, create a cross-section in the RSECTION program and then import it into RFEM/RSTAB. Depending on the design standard used, you can select from various design formats. This includes, for example, the equivalent stress analysis.
With a license for RSECTION and Effective Sections, you can also perform the design checks while taking into account the effective cross-section properties according to EN 1993‑1‑5.
Did you use the eigenvalue solver of the add-on to determine the critical load factor within the stability analysis? In this case, you can then display the governing mode shape of the object to be designed as a result.
In the "Shear Reinforcement" tab, you can select the option "Cross-ties over free rebars with active selection in graphic". It allows you to arrange additional cross-ties on free rebars of the longitudinal reinforcement.
You can activate or deactivate the position of the cross-ties in the Info Graphic. The cross-ties are applied for the ultimate limit state design and the structural design checks. They are available for the design according to EN 1992‑1‑1.
Design of tension, compression, bending, shear, torsion, and combined internal forces
Consideration of a notch
Design of compression perpendicular to the grain on the end and intermediate supports with (EC 5) and without reinforcement elements (fully threaded screws)
Optional shear force reduction at the support (see the Product Feature)
Design of curved and tapered members
Consideration of higher strengths for similar components that are close together (factor ksys according to EN 1995‑1‑1, 6.6(1)-(3))
Option to increase shear resistance for softwood timber according to DIN EN 1995‑1‑1:NA NDP to 6.1.7(2)
Stability analyses for flexural buckling, torsional buckling, and flexural-torsional buckling under compression
Import of the effective lengths from the calculation using the Structure Stability add-on
Graphical input and check of the defined nodal supports and effective lengths for stability analysis
Determination of the equivalent member lengths for tapered members
Consideration of Lateral-Torsional Bracing Position
Lateral-torsional buckling analysis of the structural components subjected to moment loading
Depending on the standard, a choice between user-defined input of Mcr, analytical method from the standard, and use of internal eigenvalue solver
Consideration of a shear panel and a rotational restraint when using the eigenvalue solver
Graphical display of a mode shape if the eigenvalue solver was used
Stability analysis of structural components with the combined compression and bending stress, depending on the design standard
Comprehensible calculation of all necessary coefficients, such as the factors for considering moment distribution or interaction factors
Alternative consideration of all effects for the stability analysis when determining internal forces in RFEM/RSTAB (second-order analysis, imperfections, stiffness reduction, possibly in combination with the Torsional Warping (7 DOF) add-on)
Your options in timber design are diverse. You can consider cut-to-grain angles, transverse tension stresses, and volume-dependent radii of curvature for tapered and curved members. To design the area of the grain cut, the strength is adjusted accordingly in the case of bending tension or bending pressure. In order to also allow you to perform a stability analysis with the equivalent member method, the height to determine the effective and lateral-torsional buckling lengths is set at a distance of 0.65 × h to the actual design point.
The Concrete Design add-on allows you to design fiber-reinforced concrete components according to the guideline "DAfStb Steel Fiber-Reinforced Concrete".
You can use this option for the design according to EN 1992‑1‑1. The design according to the DAfStb guideline is carried out once the concrete of the "Fiber Concrete" type has been assigned to the reinforced structural component.
Foundations are assigned graphically by selecting supports using the [Select] function in the graphical user interface of RFEM/RSTAB and by specifying the load cases to be designed. You can define all other foundation details quickly and easily in clearly arranged input windows.
In addition to all support forces from RFEM/RSTAB, you can specify further loads to be considered when dimensioning the foundations. The following additional loadings are available:
Pemanent surface load due to earth covering
Negative surface load; for example, due to traffic
Ground water level for uplift consideration
Concentrated loads in any position on the foundation plate
Line loads with any distribution over the foundation plate
The definition of soil layers is performed in a clearly arranged input window. An extensible library facilitates the selection of soil properties.
The elasticity can be defined either by the stiffness modulus or the modulus of elasticity and the Poisson's ratio. It is possible to define any number of soil layers. You can assign the layers to the building graphically or by entering the relevant coordinates.